Fault detection and location of power transmission lines using intelligent distance relay

The aim of this paper is to design a three-phase distance relay using an adaptive neuro-fuzzy inference system algorithm (ANFIS). The proposed relay is used to protect the power transmission lines where they are subjected to faults continuously. These faults may produce a high electric current which...

Full description

Saved in:
Bibliographic Details
Main Authors: Al Kazzaz, Sa'ad Ahmed S. (Author), Ismaeel, Ibrahim (Author), Mohammed, Karam Khairullah (Author)
Other Authors: university of Mosul (Contributor)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2020-06-01.
Subjects:
Online Access:Get Fulltext
Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02640 am a22003133u 4500
001 0 nhttps:__ijpeds.iaescore.com_index.php_IJPEDS_article_downloadSuppFile_20244_2770
042 |a dc 
100 1 0 |a Al Kazzaz, Sa'ad Ahmed S.  |e author 
100 1 0 |a university of Mosul  |e contributor 
700 1 0 |a Ismaeel, Ibrahim  |e author 
700 1 0 |a Mohammed, Karam Khairullah  |e author 
245 0 0 |a Fault detection and location of power transmission lines using intelligent distance relay 
260 |b Institute of Advanced Engineering and Science,   |c 2020-06-01. 
500 |a https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20244 
520 |a The aim of this paper is to design a three-phase distance relay using an adaptive neuro-fuzzy inference system algorithm (ANFIS). The proposed relay is used to protect the power transmission lines where they are subjected to faults continuously. These faults may produce a high electric current which leads to high damage in power system equipment. The relay is used to detect the transmission line faults by measuring the voltage and current values for each phase. The line impedance is then calculated to detect the faults and issue instantaneous trip signal to circuit breaker, to separate the fault zone of the transmission line without affecting the work of other relays. To isolate the faulty line without affecting the other lines within the network the relays were trained using adaptive neuro-fuzzy inference system (ANFIS). The obtained results through this work show that the designated distance relay with (ANFIS) algorithm has the ability to detect the faults occurrence, recognize it from the cases of the disturbance and to isolate only the fault zone without affecting the work of other relays in system. 
540 |a Copyright (c) 2019 Institute of Advanced Engineering and Science 
540 |a http://creativecommons.org/licenses/by-sa/4.0 
546 |a eng 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 2: June 2020; 726-734 
786 0 |n 2722-256X 
786 0 |n 2088-8694 
786 0 |n 10.11591/ijpeds.v11.i2 
787 0 |n https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20244/13081 
787 0 |n https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/20244/2770 
856 4 1 |u https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20244/13081  |z Get Fulltext 
856 4 1 |u https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/20244/2770  |z Get Fulltext