EFEK PENAMBAHAN EVAPORATOR PADA ATMOSPHERE WATER HARVESTER (AWH) TERHADAP PERFORMA SISTEM

Atmosphere Water Harvester (AWH) was investigated to get water collected from air in elevated performance. Improvement was performed by introducing a series-arrangement of two evaporators. Air flew through the evaporators in cross-flow. This arrangement would influence performance of the AWH system...

Full description

Saved in:
Bibliographic Details
Main Authors: Mrihardjono, Juli (Author), Ariwibowo, Didik (Author), Sutrisno, Sutrisno (Author), Tadeus, Dista Yoel (Author)
Format: EJournal Article
Published: Vocational School Diponegoro University, 2021-04-30.
Subjects:
Online Access:Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02359 am a22002773u 4500
001 GT_UNDIP_33448_19546
042 |a dc 
100 1 0 |a Mrihardjono, Juli  |e author 
700 1 0 |a Ariwibowo, Didik  |e author 
700 1 0 |a Sutrisno, Sutrisno  |e author 
700 1 0 |a Tadeus, Dista Yoel  |e author 
245 0 0 |a EFEK PENAMBAHAN EVAPORATOR PADA ATMOSPHERE WATER HARVESTER (AWH) TERHADAP PERFORMA SISTEM 
260 |b Vocational School Diponegoro University,   |c 2021-04-30. 
500 |a https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/33448 
520 |a Atmosphere Water Harvester (AWH) was investigated to get water collected from air in elevated performance. Improvement was performed by introducing a series-arrangement of two evaporators. Air flew through the evaporators in cross-flow. This arrangement would influence performance of the AWH system in title of COP, MHI, and specific energy consumption. The AWH was designed using vapor compression refrigeration system. Parameter measured to the system were refrigerant temperature in suction and discharge line, inlet and outlet pipe wall temperatures at evaporator and condenser, air velocity enter into evaporator, and electrical energy consumption. Instrument used in this research were refrigerant pressure-temperature gauge, K-type digital thermometer, digital fan anemometer, thermo-hygro meter, and kWh meter. Air temperature and RH data were 36,5 oC, 40%, and 19 oC, 42 %  for inlet and outlet air stram at evaporator, subsequently. With air velocity 1.5 m/s, the COP of the system was 3.7. Water collected  from AWH was 1.1 litres/hour with energy consumption of 1.24 kWh. The AWH could be considered as a water harvester with value of specific energy of 1.13 kWh/litre and MHI of 0,2. 
540 |a Copyright (c) 2021 Gema Teknologi 
546 |a eng 
690 |a water harvester; refrigeration; energy consumption; COP; MHI 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n Gema Teknologi; Vol 21, No 2 (2021): October 2020 - April 2021; 74 - 80 
786 0 |n 2656-582X 
786 0 |n 0852-0232 
787 0 |n https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/33448/19546 
856 4 1 |u https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/33448/19546  |z Get Fulltext