PERENCANAAN FILTER PASIF UNTUK MENINGKATKAN KUALITAS DAYA LISTRIK DI KAMPUS DIPLOMA III FAKULTAS TEKNIK UNDIP

Arkhan Subari, Saiful Manan, in this paper explain that most electronic equipment is non-linear load. Likewise with the equipment in campus buildings Diploma III Faculty of Engineering. Non-linear load is a load that has a voltage waveform supplied from non sinusiodal although sinusoidal voltage. No...

Full description

Saved in:
Bibliographic Details
Main Authors: Subari, Arkhan (Author), Manan, Saiful (Author)
Format: EJournal Article
Published: Vocational School Diponegoro University, 2015-08-04.
Subjects:
Online Access:Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02212 am a22002413u 4500
001 GT_UNDIP_8932_7253
042 |a dc 
100 1 0 |a Subari, Arkhan  |e author 
100 1 0 |e contributor 
700 1 0 |a Manan, Saiful  |e author 
245 0 0 |a PERENCANAAN FILTER PASIF UNTUK MENINGKATKAN KUALITAS DAYA LISTRIK DI KAMPUS DIPLOMA III FAKULTAS TEKNIK UNDIP 
260 |b Vocational School Diponegoro University,   |c 2015-08-04. 
500 |a https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/8932 
520 |a Arkhan Subari, Saiful Manan, in this paper explain that most electronic equipment is non-linear load. Likewise with the equipment in campus buildings Diploma III Faculty of Engineering. Non-linear load is a load that has a voltage waveform supplied from non sinusiodal although sinusoidal voltage. Non-sinusoidal wave causes the shape of the voltage becomes distorted or defects that result in decreased quality of power. The defect wave called harmonics. To dampen harmonics on non-linear load can be used filter. With the addition of a filter on the power system, then the waves of unwanted harmonics can be suppressed as small as possible. In addition, harmonic filter at the fundamental frequency can compensate for reactive power and is used to improve the power factor of the system. From the measurement results in the Diploma Program Campus FT Undip found that the influence of harmonic waves big enough. THDv reached 32.13% while the THDi amounted to 7.85%. It affects so cos phi cos phi measured just 0.72. After the installation of a passive filter, the value THDv and THDi be good lebik ie 1.61% and 0.39% to reach 0.94 cos phi measured. Key word: non-linear loads, non-sinusoidal waveform, harmonics, power factor, filter LC 
546 |a eng 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n Gema Teknologi; Vol 17, No 4 (2014): October 2013 - April 2014 
786 0 |n 2656-582X 
786 0 |n 0852-0232 
787 0 |n https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/8932/7253 
856 4 1 |u https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/8932/7253  |z Get Fulltext