Input switched closed-loop single phase ĈUK AC to DC converter with improved power quality
A new closed loop AC to DC ĈUK converter is presented in this paper. The conventional ĈUK AC to DC converter has no feedback circuit. Thereby, the output voltage of the converter changes while changing the load. The proposed closed loop converter can regulate voltage with the variation of load ove...
Zapisane w:
Główni autorzy: | , , , |
---|---|
Format: | EJournal Article |
Wydane: |
Institute of Advanced Engineering and Science,
2019-09-01.
|
Hasła przedmiotowe: | |
Dostęp online: | Get Fulltext |
Etykiety: |
Dodaj etykietę
Nie ma etykietki, Dołącz pierwszą etykiete!
|
LEADER | 02226 am a22003013u 4500 | ||
---|---|---|---|
001 | IJPEDS_15970_12861 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Arifin, Md. Shamsul |e author |
100 | 1 | 0 | |e contributor |
700 | 1 | 0 | |a Mohammad, Nur |e author |
700 | 1 | 0 | |a Khalil, Mohammad Ibrahim |e author |
700 | 1 | 0 | |a Alam, Mohammad Jahangir |e author |
245 | 0 | 0 | |a Input switched closed-loop single phase ĈUK AC to DC converter with improved power quality |
260 | |b Institute of Advanced Engineering and Science, |c 2019-09-01. | ||
500 | |a https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15970 | ||
520 | |a A new closed loop AC to DC ĈUK converter is presented in this paper. The conventional ĈUK AC to DC converter has no feedback circuit. Thereby, the output voltage of the converter changes while changing the load. The proposed closed loop converter can regulate voltage with the variation of load over a wide range. Moreover, the power factor and Total Harmonic Distortion (THD) of the supply side current found quite satisfactory from this closed loop ĈUK converter. The converter operates in four steps with a different combination of voltage polarities and switching states. The feedback path consists of a voltage control loop and a current control loop. The closed loop ĈUK converter in this study is compared with the open loop version. Additionally, the comparison is made with the conventional converter of the same topology. The effectiveness in terms of power factor and THD of the proposed converter is verified using simulation results. | ||
540 | |a Copyright (c) 2019 Institute of Advanced Engineering and Science | ||
540 | |a http://creativecommons.org/licenses/by-sa/4.0 | ||
546 | |a eng | ||
655 | 7 | |a info:eu-repo/semantics/article |2 local | |
655 | 7 | |a info:eu-repo/semantics/publishedVersion |2 local | |
655 | 7 | |2 local | |
786 | 0 | |n International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 10, No 3: September 2019; 1373-1381 | |
786 | 0 | |n 2722-256X | |
786 | 0 | |n 2088-8694 | |
786 | 0 | |n 10.11591/ijpeds.v10.i3 | |
787 | 0 | |n https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15970/12861 | |
856 | 4 | 1 | |u https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15970/12861 |z Get Fulltext |