Enhancement of voltage regulation using a 7-Level inverter based electric spring with reduced number of switches

Electric Springs has been testified recently to enhance voltage regulation in distribution systems using demand side management. In this paper, a 7-level Multilevel Inverter (MLI) with a resonant switched capacitor Converter based on sinusoidal PWM, is implemented to analyze the performance of an el...

Full description

Saved in:
Bibliographic Details
Main Authors: Deepika, K. K. (Author), Kumar, J. Vijaya (Author), Rao, G. Kesava (Author)
Other Authors: Vignan's Institute of Information Technology (Contributor)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2020-06-01.
Subjects:
Online Access:Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02071 am a22002893u 4500
001 IJPEDS_19568_13061
042 |a dc 
100 1 0 |a Deepika, K. K.  |e author 
100 1 0 |a Vignan's Institute of Information Technology  |e contributor 
700 1 0 |a Kumar, J. Vijaya  |e author 
700 1 0 |a Rao, G. Kesava  |e author 
245 0 0 |a Enhancement of voltage regulation using a 7-Level inverter based electric spring with reduced number of switches 
260 |b Institute of Advanced Engineering and Science,   |c 2020-06-01. 
500 |a https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/19568 
520 |a Electric Springs has been testified recently to enhance voltage regulation in distribution systems using demand side management. In this paper, a 7-level Multilevel Inverter (MLI) with a resonant switched capacitor Converter based on sinusoidal PWM, is implemented to analyze the performance of an electric spring under voltage variations at PCC. By the proposed MLI based ES, voltage regulation of critical load voltage is studied for voltage sag and swell conditions. Remarkable features of the proposed topology are maintaining voltage balance in input capacitors and reduction of power components. Simulations have been done in MATLAB/Simulink on distribution system with DGs equipped with MLI based ES under line voltage anomalies. Tested results are analyzed with THD% in critical load voltage. 
540 |a Copyright (c) 2019 Institute of Advanced Engineering and Science 
540 |a http://creativecommons.org/licenses/by-sa/4.0 
546 |a eng 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 2: June 2020; 555-565 
786 0 |n 2722-256X 
786 0 |n 2088-8694 
786 0 |n 10.11591/ijpeds.v11.i2 
787 0 |n https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/19568/13061 
856 4 1 |u https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/19568/13061  |z Get Fulltext