Selection the optimum place of FACTS devices using fuzzy control system

In this paper, the voltage stability of the power system is studied during fault conditions. Enhancement of the system's stability will be achieved by utilizing Flexible AC transmission systems (FACTS) controllers at the best place in the system. The optimum placement of (FACTS) controllers occ...

Full description

Saved in:
Bibliographic Details
Main Authors: Hameed, Jawad (Author), Mohammed, Hameed Ali (Author), Saeed, Amer T. (Author)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2020-12-01.
Subjects:
Online Access:Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02406 am a22002893u 4500
001 IJPEDS_20644_13259
042 |a dc 
100 1 0 |a Hameed, Jawad  |e author 
100 1 0 |e contributor 
700 1 0 |a Mohammed, Hameed Ali  |e author 
700 1 0 |a Saeed, Amer T.  |e author 
245 0 0 |a Selection the optimum place of FACTS devices using fuzzy control system 
260 |b Institute of Advanced Engineering and Science,   |c 2020-12-01. 
500 |a https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20644 
520 |a In this paper, the voltage stability of the power system is studied during fault conditions. Enhancement of the system's stability will be achieved by utilizing Flexible AC transmission systems (FACTS) controllers at the best place in the system. The optimum placement of (FACTS) controllers occurred on the most affected bus by the fault in the system (weakest bus). Two approaches have been used in this study to effectively obtain the best location of the (FACTS) controllers in the system. The first method is based on computing the deviation which occurs in the active power and reactive power due to the fault at each load bus at a time. Whereas the second method is performed through exploiting a MATLAB fuzzy set technique utilizing two indices: Line Flow Index (LFI) and Voltage Profile Index (VPI) during fault and steady-state conditions. The results show that both of these indices resulted in the same bus as the best location. Remedial actions in the attempt at improving in the stability of the power system are discussed taking the advantage of using (FACTS) compensation (SVC) and (STATCOM) at the most vulnerable system buses. In this work, MATLAB program with an IEEE 24 bus system is examined. 
540 |a Copyright (c) 2020 Institute of Advanced Engineering and Science 
540 |a http://creativecommons.org/licenses/by-sa/4.0 
546 |a eng 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 4: December 2020; 1805-1815 
786 0 |n 2722-256X 
786 0 |n 2088-8694 
786 0 |n 10.11591/ijpeds.v11.i4 
787 0 |n https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20644/13259 
856 4 1 |u https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20644/13259  |z Get Fulltext