Enhanced DTC induction motor drives for THD minimization performance improvement with multilevel inverter

Direct torque control (DTC) is a method applied in induction motor (IM) drives to control the speed and torque of IM accurately and independently without feedback signal. However, in fast fourier transform (FFT) analysis, the total harmonic distortion (THD) of the IM drives is high in DTC method wit...

Full description

Saved in:
Bibliographic Details
Main Authors: Chien, Siong Kai (Author), Sim, Sy Yi (Author), Utomo, Wahyu Mulyo (Author), Kek, Sie Long (Author), Mustafa, Farahiyah (Author), Zambri, Nor Aira (Author), Siang, Alvin John Lim Meng (Author), Sim, Gia Yi (Author)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2022-03-01.
Subjects:
Online Access:Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02719 am a22003613u 4500
001 IJPEDS_21659_13722
042 |a dc 
100 1 0 |a Chien, Siong Kai  |e author 
100 1 0 |e contributor 
700 1 0 |a Sim, Sy Yi  |e author 
700 1 0 |a Utomo, Wahyu Mulyo  |e author 
700 1 0 |a Kek, Sie Long  |e author 
700 1 0 |a Mustafa, Farahiyah  |e author 
700 1 0 |a Zambri, Nor Aira  |e author 
700 1 0 |a Siang, Alvin John Lim Meng  |e author 
700 1 0 |a Sim, Gia Yi  |e author 
245 0 0 |a Enhanced DTC induction motor drives for THD minimization performance improvement with multilevel inverter 
260 |b Institute of Advanced Engineering and Science,   |c 2022-03-01. 
500 |a https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21659 
520 |a Direct torque control (DTC) is a method applied in induction motor (IM) drives to control the speed and torque of IM accurately and independently without feedback signal. However, in fast fourier transform (FFT) analysis, the total harmonic distortion (THD) of the IM drives is high in DTC method with conventional inverter (CI). Therefore, the purpose of this study is to minimize the THD without affecting the drive's performance. A DTC IM drive with multilevel inverter (MLI) is proposed in this study to reduce THD and preserve good speed and torque response of IM simultaneously. DTC IM drive with proposed MLI based THD minimization has several advantages over the DTC IM drive with CI, including higher generated output voltage with low distortion, operate under low switching frequency, and work with renewable energy. In order to prove the effectiveness of the proposed MLI based THD minimization in DTC IM drive, MATLAB Simulink is used to investigate the response of the IM drive and THD under different operating condition. From this study, proposed MLI based THD minimization DTC IM drive is able to reduce THD with a maximum of 13% in low speed operation as compared to DTC IM drive with CI. 
540 |a Copyright (c) 2022 Institute of Advanced Engineering and Science 
540 |a http://creativecommons.org/licenses/by-sa/4.0 
546 |a eng 
690 |a direct torque control; multilevel inverter; total harmonic distortion; 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 1: March 2022; 93-101 
786 0 |n 2722-256X 
786 0 |n 2088-8694 
786 0 |n 10.11591/ijpeds.v13.i1 
787 0 |n https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21659/13722 
856 4 1 |u https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21659/13722  |z Get Fulltext