A New Compensation Control Strategy for Grid-connected Wind Turbine and Fuel Cell Inverters in a Microgrid

The use of a new control method for grid-connected inverters for reducing the output current harmonic distortion in a wide range of grid-connected distributed generation (DG) applications, including wind turbine (WT) and fuel cell (FC) inverters is proposed in this paper. The control method designed...

Full description

Saved in:
Bibliographic Details
Main Authors: Naderipour, A. (Author), Mohd Zin, A. A. (Author), Habibuddin, M. H. (Author), Moradi, M. (Author), Miveh, M. (Author), Afrouzi, H. N. (Author)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2017-03-01.
Subjects:
Online Access:Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The use of a new control method for grid-connected inverters for reducing the output current harmonic distortion in a wide range of grid-connected distributed generation (DG) applications, including wind turbine (WT) and fuel cell (FC) inverters is proposed in this paper. The control method designed to eliminate main harmonics in a microgrid (MG) and between MG and point of common coupling (PCC) and responsible for the correction of the system unbalance. Another advantage of the proposed control method is that it can be easily adopted into the DG control system without the installation of extra hardware. The proposed control method is comprised of the synchronous reference frame method (SRF). Results from the proposed control method are provided to show the feasibility of the proposed approach.
Item Description:https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6155