Verification of MATLAB/Simulink Power Cable Modelling with Experimental Analysis
Cross-linked polyethylene (XLPE) power cable is commonly used as the medium for transmitting power supply in the power system network. However, frequent exposure of XLPE cable to the high voltage causes its insulation to degrade over time leading to electricity outages. Degradation of cable can be p...
Saved in:
Main Authors: | , , , |
---|---|
Format: | EJournal Article |
Published: |
Institute of Advanced Engineering and Science,
2018-08-01.
|
Subjects: | |
Online Access: | Get fulltext |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
LEADER | 02392 am a22003253u 4500 | ||
---|---|---|---|
001 | ijeecs12819_8870 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Kuan, Tze Mei |e author |
100 | 1 | 0 | |e contributor |
700 | 1 | 0 | |a Sulaiman, Suhaila |e author |
700 | 1 | 0 | |a Ariffin, Azrul Mohd. |e author |
700 | 1 | 0 | |a Shamsuddin, Wan Mohamad Shakir Wan |e author |
245 | 0 | 0 | |a Verification of MATLAB/Simulink Power Cable Modelling with Experimental Analysis |
260 | |b Institute of Advanced Engineering and Science, |c 2018-08-01. | ||
500 | |a https://ijeecs.iaescore.com/index.php/IJEECS/article/view/12819 | ||
520 | |a Cross-linked polyethylene (XLPE) power cable is commonly used as the medium for transmitting power supply in the power system network. However, frequent exposure of XLPE cable to the high voltage causes its insulation to degrade over time leading to electricity outages. Degradation of cable can be prevented if regular maintenance is performed using the accurate assessment method. This study models and simulates a cable system comprising of three cable sections connected by two un-degraded cable joints. This model aims to assess defect along the tested cable with the application of time domain reflectometry (TDR) technique. A series of simulations are conducted by varying the cable insulation condition to study its influence on the cable joint reflection. These simulation results from MATLAB/Simulink are validated against the actual TDR experimental results. The identical results shown between the simulation and experimental results indicate that the cable model is valid and can be used to assess the condition of a cable. | ||
540 | |a Copyright (c) 2018 Institute of Advanced Engineering and Science | ||
540 | |a http://creativecommons.org/licenses/by-nc/4.0 | ||
546 | |a eng | ||
690 | |||
690 | |a Cable defects; cables joints; MATLAB/Simulink; time domain reflectometry | ||
655 | 7 | |a info:eu-repo/semantics/article |2 local | |
655 | 7 | |a info:eu-repo/semantics/publishedVersion |2 local | |
655 | 7 | |2 local | |
786 | 0 | |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 11, No 2: August 2018; 622-629 | |
786 | 0 | |n 2502-4760 | |
786 | 0 | |n 2502-4752 | |
786 | 0 | |n 10.11591/ijeecs.v11.i2 | |
787 | 0 | |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/12819/8870 | |
856 | 4 | 1 | |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/12819/8870 |z Get fulltext |