Verification of MATLAB/Simulink Power Cable Modelling with Experimental Analysis

Cross-linked polyethylene (XLPE) power cable is commonly used as the medium for transmitting power supply in the power system network. However, frequent exposure of XLPE cable to the high voltage causes its insulation to degrade over time leading to electricity outages. Degradation of cable can be p...

Full description

Saved in:
Bibliographic Details
Main Authors: Kuan, Tze Mei (Author), Sulaiman, Suhaila (Author), Ariffin, Azrul Mohd (Author), Shamsuddin, Wan Mohamad Shakir Wan (Author)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2018-08-01.
Subjects:
Online Access:Get fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02392 am a22003253u 4500
001 ijeecs12819_8870
042 |a dc 
100 1 0 |a Kuan, Tze Mei  |e author 
100 1 0 |e contributor 
700 1 0 |a Sulaiman, Suhaila  |e author 
700 1 0 |a Ariffin, Azrul Mohd.  |e author 
700 1 0 |a Shamsuddin, Wan Mohamad Shakir Wan  |e author 
245 0 0 |a Verification of MATLAB/Simulink Power Cable Modelling with Experimental Analysis 
260 |b Institute of Advanced Engineering and Science,   |c 2018-08-01. 
500 |a https://ijeecs.iaescore.com/index.php/IJEECS/article/view/12819 
520 |a Cross-linked polyethylene (XLPE) power cable is commonly used as the medium for transmitting power supply in the power system network. However, frequent exposure of XLPE cable to the high voltage causes its insulation to degrade over time leading to electricity outages. Degradation of cable can be prevented if regular maintenance is performed using the accurate assessment method. This study models and simulates a cable system comprising of three cable sections connected by two un-degraded cable joints. This model aims to assess defect along the tested cable with the application of time domain reflectometry (TDR) technique. A series of simulations are conducted by varying the cable insulation condition to study its influence on the cable joint reflection. These simulation results from MATLAB/Simulink are validated against the actual TDR experimental results. The identical results shown between the simulation and experimental results indicate that the cable model is valid and can be used to assess the condition of a cable. 
540 |a Copyright (c) 2018 Institute of Advanced Engineering and Science 
540 |a http://creativecommons.org/licenses/by-nc/4.0 
546 |a eng 
690
690 |a Cable defects; cables joints; MATLAB/Simulink; time domain reflectometry 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 11, No 2: August 2018; 622-629 
786 0 |n 2502-4760 
786 0 |n 2502-4752 
786 0 |n 10.11591/ijeecs.v11.i2 
787 0 |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/12819/8870 
856 4 1 |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/12819/8870  |z Get fulltext