Passive sensor frequency selective surface for structural health monitoring

Structural health monitoring (SHM) technologies have attained attention to monitor civil structures. SHM sensor systems have been used in various civil structures such as bridges, buildings, tunnels and so on. However the previous sensor for SHM is wired and encounter with problem to cover large are...

Full description

Saved in:
Bibliographic Details
Main Authors: Mustafa, F.H.W (Author), Azemi, S.N (Author), Jamlos, M.F (Author), Al-Hadi, A.A (Author), Soh, P.J (Author)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2019-05-01.
Subjects:
Online Access:Get fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02570 am a22003373u 4500
001 ijeecs16728_11937
042 |a dc 
100 1 0 |a Mustafa, F.H.W.  |e author 
100 1 0 |e contributor 
700 1 0 |a Azemi, S.N.  |e author 
700 1 0 |a Jamlos, M.F.  |e author 
700 1 0 |a Al-Hadi, A.A.  |e author 
700 1 0 |a Soh, P.J.  |e author 
245 0 0 |a Passive sensor frequency selective surface for structural health monitoring 
260 |b Institute of Advanced Engineering and Science,   |c 2019-05-01. 
500 |a https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16728 
520 |a Structural health monitoring (SHM) technologies have attained attention to monitor civil structures. SHM sensor systems have been used in various civil structures such as bridges, buildings, tunnels and so on. However the previous sensor for SHM is wired and encounter with problem to cover large areas. Therefore, wireless sensor was introduced for SHM to reduce network connecting problem. Wireless sensors for Structural Health monitoring are new technology and have many advantages to overcome the drawback of conventional and wired sensor. This project proposed passive wireless SHM sensor using frequency selective surface (FSS) as an alternative to conventional sensors. The electromagnetic wave characteristic of FSS will change by geometrical changes of FSS due to mechanical strain or structural failure. The changes feature is used as a sensing function without any connecting wires. Two type of design which are circular ring and square loop along with the transmission and reflection characteristics of SHM using FSS were discussed in this project. A simulation process has shown that incident angle characteristics can be use as a data for SHM application. 
540 |a Copyright (c) 2018 Institute of Advanced Engineering and Science 
540 |a http://creativecommons.org/licenses/by-nc/4.0 
546 |a eng 
690
690 |a Frequency Selective Surface, Incident angle, Structural Health Monitoring, Building damage detection, Sensor technology. 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 14, No 2: May 2019; 744-750 
786 0 |n 2502-4760 
786 0 |n 2502-4752 
786 0 |n 10.11591/ijeecs.v14.i2 
787 0 |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16728/11937 
856 4 1 |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16728/11937  |z Get fulltext