Comparison between PI, PR+HC, and modified PR+HC current controller in inverter system

This paper presents the comparison between proportional integral (PI) current controller, proportional resonance and harmonic compensator (PR+HC) current controller and modified PR+HC current controller in the inverter system. Power electronic components like inverter and current controller uses in...

Full description

Saved in:
Bibliographic Details
Main Authors: Salimin, S. (Author), Armstrong, M. (Author), Jumaat, S.A (Author), Hamdan, R. (Author)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2019-03-01.
Subjects:
Online Access:Get fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This paper presents the comparison between proportional integral (PI) current controller, proportional resonance and harmonic compensator (PR+HC) current controller and modified PR+HC current controller in the inverter system. Power electronic components like inverter and current controller uses in the system produce unwanted harmonics that affect the quality of distribution power network. In this study, development and simulation of current controller using conventional proportional integral (PI), the selective harmonic compensation scheme (PR+HC), and modified version of the latter are considered so to overcome these harmonics injection. Modification is by adding control parameter randomisation technique to the PR+HC scheme. Results compare the three controllers and proved that with modification to the selective harmonic compensation scheme, the overall current THD can be reduced
Item Description:https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16999