Comparison between PI, PR+HC, and modified PR+HC current controller in inverter system

This paper presents the comparison between proportional integral (PI) current controller, proportional resonance and harmonic compensator (PR+HC) current controller and modified PR+HC current controller in the inverter system. Power electronic components like inverter and current controller uses in...

Full description

Saved in:
Bibliographic Details
Main Authors: Salimin, S. (Author), Armstrong, M. (Author), Jumaat, S.A (Author), Hamdan, R. (Author)
Format: EJournal Article
Published: Institute of Advanced Engineering and Science, 2019-03-01.
Subjects:
Online Access:Get fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02196 am a22003253u 4500
001 ijeecs16999_10860
042 |a dc 
100 1 0 |a Salimin, S.  |e author 
100 1 0 |e contributor 
700 1 0 |a Armstrong, M.  |e author 
700 1 0 |a Jumaat, S.A.  |e author 
700 1 0 |a Hamdan, R.  |e author 
245 0 0 |a Comparison between PI, PR+HC, and modified PR+HC current controller in inverter system 
260 |b Institute of Advanced Engineering and Science,   |c 2019-03-01. 
500 |a https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16999 
520 |a This paper presents the comparison between proportional integral (PI) current controller, proportional resonance and harmonic compensator (PR+HC) current controller and modified PR+HC current controller in the inverter system. Power electronic components like inverter and current controller uses in the system produce unwanted harmonics that affect the quality of distribution power network. In this study, development and simulation of current controller using conventional proportional integral (PI), the selective harmonic compensation scheme (PR+HC), and modified version of the latter are considered so to overcome these harmonics injection. Modification is by adding control parameter randomisation technique to the PR+HC scheme. Results compare the three controllers and proved that with modification to the selective harmonic compensation scheme, the overall current THD can be reduced 
540 |a Copyright (c) 2018 Institute of Advanced Engineering and Science 
540 |a http://creativecommons.org/licenses/by-nc/4.0 
546 |a eng 
690
690 |a Current controller, Harmonics, Inverter system 
655 7 |a info:eu-repo/semantics/article  |2 local 
655 7 |a info:eu-repo/semantics/publishedVersion  |2 local 
655 7 |2 local 
786 0 |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 13, No 3: March 2019; 1167-1174 
786 0 |n 2502-4760 
786 0 |n 2502-4752 
786 0 |n 10.11591/ijeecs.v13.i3 
787 0 |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16999/10860 
856 4 1 |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/16999/10860  |z Get fulltext