Chaotic immune symbiotic organisms search for SVC installation in voltage security control
Parallel with the urbanization of the world, energy demand in the world also increased. The increase in energy demand will require a power system to be operated near its stability limit. To mitigate the problem, Flexible Alternating Current Transmission System (FACTS) devices can be installed as a c...
Saved in:
Main Authors: | , , , |
---|---|
Format: | EJournal Article |
Published: |
Institute of Advanced Engineering and Science,
2019-11-01.
|
Subjects: | |
Online Access: | Get fulltext |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
LEADER | 02811 am a22003253u 4500 | ||
---|---|---|---|
001 | ijeecs19985_13090 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Mohamad Zamani, Mohamad Khairuzzaman |e author |
100 | 1 | 0 | |e contributor |
700 | 1 | 0 | |a Musirin, Ismail |e author |
700 | 1 | 0 | |a Suliman, Saiful Izwan |e author |
700 | 1 | 0 | |a Murtadha Othman, Muhammad |e author |
245 | 0 | 0 | |a Chaotic immune symbiotic organisms search for SVC installation in voltage security control |
260 | |b Institute of Advanced Engineering and Science, |c 2019-11-01. | ||
500 | |a https://ijeecs.iaescore.com/index.php/IJEECS/article/view/19985 | ||
520 | |a Parallel with the urbanization of the world, energy demand in the world also increased. The increase in energy demand will require a power system to be operated near its stability limit. To mitigate the problem, Flexible Alternating Current Transmission System (FACTS) devices can be installed as a compensation scheme to improve voltage security in a power system. For an effective compensation, FACTS devices should be optimally allocated in a power system. Although optimization techniques can be implemented to optimally allocate these devices, problems have been reported which would affect the performance of the optimization techniques in terms of producing high quality solutions. This paper presents the implementation of Chaotic Immune Symbiotic Organisms Search for solving optimal Static VAr Compensator (SVC) allocation problem for voltage security control. The optimization is validated in IEEE 26-Bus Reliability Test System (RTS) realizes the capability of CISOS in solving the optimization problem. Comparative studies with respect to Particle Swarm Optimization (PSO) and Evolutionary Programming (EP) resulting in good agreement on the results and demonstrated superior performance of CISOS. Results of the study can be beneficial to power system community in terms of compensation planning prior to real world implementation. | ||
540 | |a Copyright (c) 2019 Institute of Advanced Engineering and Science | ||
540 | |a http://creativecommons.org/licenses/by-nc/4.0 | ||
546 | |a eng | ||
690 | |||
690 | |a Chaotic immune symbiotic organisms search (CISOS), Static VAr compensator (SVC), Total voltage deviation index (TVDI), Fast voltage stability index (FVSI) | ||
655 | 7 | |a info:eu-repo/semantics/article |2 local | |
655 | 7 | |a info:eu-repo/semantics/publishedVersion |2 local | |
655 | 7 | |2 local | |
786 | 0 | |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 16, No 2: November 2019; 623-630 | |
786 | 0 | |n 2502-4760 | |
786 | 0 | |n 2502-4752 | |
786 | 0 | |n 10.11591/ijeecs.v16.i2 | |
787 | 0 | |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/19985/13090 | |
856 | 4 | 1 | |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/19985/13090 |z Get fulltext |