Active tremor control in human-like hand tremor using fuzzy logic
Tremoris the vibration in sinusoidal orientation that is experienced regularly by a person with Parkinson's disease (PD), which disturbs their daily activities. One solution that may be used to counter this tremor effect is by developing an active tremor control system in LabVIEW for linear voi...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | , |
Format: | EJournal Article |
Published: |
Institute of Advanced Engineering and Science,
2021-10-01.
|
Subjects: | |
Online Access: | Get fulltext |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
LEADER | 02937 am a22003613u 4500 | ||
---|---|---|---|
001 | ijeecs25103_15582 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Jamaludin, Hafiz Bin |e author |
100 | 1 | 0 | |a Universiti Putra Malaysia |q (UPM) |e contributor |
100 | 1 | 0 | |a Malaysian Ministry of Education |q (MOE) |e contributor |
700 | 1 | 0 | |a As'arry, Azizan |e author |
700 | 1 | 0 | |a Musab, R. |e author |
700 | 1 | 0 | |a Rezali, Khairil Anas Md |e author |
700 | 1 | 0 | |a Ahmad, Raja Mohd Kamil Bin Raja |e author |
700 | 1 | 0 | |a Zain, Mohd Zarhamdy Bin Md. |e author |
245 | 0 | 0 | |a Active tremor control in human-like hand tremor using fuzzy logic |
260 | |b Institute of Advanced Engineering and Science, |c 2021-10-01. | ||
500 | |a https://ijeecs.iaescore.com/index.php/IJEECS/article/view/25103 | ||
520 | |a Tremoris the vibration in sinusoidal orientation that is experienced regularly by a person with Parkinson's disease (PD), which disturbs their daily activities. One solution that may be used to counter this tremor effect is by developing an active tremor control system in LabVIEW for linear voice coil actuator (LVCA), where the system uses proportional (P) controller and various types of fuzzy logic controller (FLC) as a hybrid controller to reduce tremor vibration. From this research, it can be concluded that the best controller for tremor reduction is the P+FLC 1st set of rules, compared to P+FLC 2nd set of rules, and P controller only, with the highest percentage of 88.39% of tremor reduction with the actual tremor vibration of PD patients as the reference result. The P+FLC 2nd set of rules has the highest percentage of tremor reduction with a value of 86.81%, whereas P controller only has the highest tremor reduction percentage of 67.10%. This percentage of tremor reduction is based on the power spectral density (PSD) values, in which it represents the intensity of the tremor vibration. This experimental study can be used as an initial step for researchers and engineers to design and develop an anti-tremor device in the future. | ||
540 | |a Copyright (c) 2021 Institute of Advanced Engineering and Science | ||
540 | |a http://creativecommons.org/licenses/by-nc/4.0 | ||
546 | |a eng | ||
690 | |a Mechanical Engineering; Control engineering | ||
690 | |a Active tremor control; Experimental study; Fuzzy logic controller; Parkinson's disease tremor; Tremor test rig; | ||
655 | 7 | |a info:eu-repo/semantics/article |2 local | |
655 | 7 | |a info:eu-repo/semantics/publishedVersion |2 local | |
655 | 7 | |2 local | |
786 | 0 | |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 24, No 1: October 2021; 108-115 | |
786 | 0 | |n 2502-4760 | |
786 | 0 | |n 2502-4752 | |
786 | 0 | |n 10.11591/ijeecs.v24.i1 | |
787 | 0 | |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/25103/15582 | |
856 | 4 | 1 | |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/25103/15582 |z Get fulltext |