A Control Strategy for Single-phase Grid-Connected Inverter with Power Quality Regulatory Function
A single-phase grid-connected inverter system based on LCL filter is established,which combines the features of inverter and active power filter. A composite control strategy for grid-connected inverter with the function of implementing reactive power compensation and harmonic compensation in the gr...
Saved in:
Main Authors: | , , , |
---|---|
Format: | EJournal Article |
Published: |
Institute of Advanced Engineering and Science,
2014-01-01.
|
Subjects: | |
Online Access: | Get fulltext |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
LEADER | 02293 am a22003013u 4500 | ||
---|---|---|---|
001 | ijeecs2997_1006 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Jiapei, Jin |e author |
100 | 1 | 0 | |e contributor |
700 | 1 | 0 | |a Tiantian, Chen |e author |
700 | 1 | 0 | |a Ling, Luo |e author |
700 | 1 | 0 | |a Shaoze, Su |e author |
245 | 0 | 0 | |a A Control Strategy for Single-phase Grid-Connected Inverter with Power Quality Regulatory Function |
260 | |b Institute of Advanced Engineering and Science, |c 2014-01-01. | ||
520 | |a A single-phase grid-connected inverter system based on LCL filter is established,which combines the features of inverter and active power filter. A composite control strategy for grid-connected inverter with the function of implementing reactive power compensation and harmonic compensation in the grid-connected power generation is proposed. Firstly, grid-connected inverter system structure and model is analyzed. A quasi-Proportional Resonant control method to gain the control of grid-connected fundamental wave current containing reactive power compensation current as well as the control of harmonic compensation currents is put forward; then the calculation methods of composite control command current based on both second order generalized integrator-quadrature signal generator (SOGI-QSG) and instantaneous reactive power theory are given. Finally, the effectiveness of the control strategy proposed in this paper is verified by simulation. DOI : http://dx.doi.org/10.11591/telkomnika.v12i1.3911 | ||
540 | |a Copyright (c) 2013 Institute of Advanced Engineering and Science | ||
540 | |a http://creativecommons.org/licenses/by-nc-nd/4.0 | ||
546 | |a eng | ||
690 | |a single-phase grid-connected inverter; harmonic compensation; harmonic compensation; SOGI-QSG; quasi-PR controller | ||
655 | 7 | |a info:eu-repo/semantics/article |2 local | |
655 | 7 | |a info:eu-repo/semantics/publishedVersion |2 local | |
655 | 7 | |2 local | |
786 | 0 | |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 12, No 1: January 2014; 225-233 | |
786 | 0 | |n 2502-4760 | |
786 | 0 | |n 2502-4752 | |
786 | 0 | |n 10.11591/ijeecs.v12.i1 | |
787 | 0 | |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/2997/1006 | |
856 | 4 | 1 | |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/2997/1006 |z Get fulltext |