Single-winding Regulation Mode of Controllable Reactor of Transformer Type
It is an important part to select the regulation mode in the design and manufacture of a controllable reactor of transformer type(CRT).Based on the circuit equations expressed by the self and mutual inductance, the piecewise expressions of the instantaneous current in work winding in the single-wind...
Saved in:
Main Authors: | , , |
---|---|
Format: | EJournal Article |
Published: |
Institute of Advanced Engineering and Science,
2014-09-01.
|
Subjects: | |
Online Access: | Get fulltext |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
LEADER | 02111 am a22003013u 4500 | ||
---|---|---|---|
001 | ijeecs3782_2115 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Yibin, Liu |e author |
700 | 1 | 0 | |a Mingxing, Tian |e author |
700 | 1 | 0 | |a Jianning, Yin |e author |
245 | 0 | 0 | |a Single-winding Regulation Mode of Controllable Reactor of Transformer Type |
260 | |b Institute of Advanced Engineering and Science, |c 2014-09-01. | ||
500 | |a https://ijeecs.iaescore.com/index.php/IJEECS/article/view/3782 | ||
520 | |a It is an important part to select the regulation mode in the design and manufacture of a controllable reactor of transformer type(CRT).Based on the circuit equations expressed by the self and mutual inductance, the piecewise expressions of the instantaneous current in work winding in the single-winding regulation mode are obtained, and then the formula for calculating the RMS of each harmonic current in work winding is derived by Fourier series decomposition. At last, the control characteristics of CRT and the curves of the RMS of harnonic currents with reference to the output power in three typical single-winding regulation modes are presented and their advantages and disadvantages are compared in the sample, which provides a reference for the design of CRT. | ||
540 | |a Copyright (c) 2014 Institute of Advanced Engineering and Science | ||
540 | |a http://creativecommons.org/licenses/by-nc-nd/4.0 | ||
546 | |a eng | ||
690 | |a Electric Engineering;Reactive Power Compensation and Voltage Control | ||
690 | |a Controllable Reactor of Transformer Type; Single-winding Regulation Mode; Harmonic Current | ||
655 | 7 | |a info:eu-repo/semantics/article |2 local | |
655 | 7 | |a info:eu-repo/semantics/publishedVersion |2 local | |
655 | 7 | |2 local | |
786 | 0 | |n Indonesian Journal of Electrical Engineering and Computer Science; Vol 12, No 9: September 2014; 6544-6550 | |
786 | 0 | |n 2502-4760 | |
786 | 0 | |n 2502-4752 | |
786 | 0 | |n 10.11591/ijeecs.v12.i9 | |
787 | 0 | |n https://ijeecs.iaescore.com/index.php/IJEECS/article/view/3782/2115 | |
856 | 4 | 1 | |u https://ijeecs.iaescore.com/index.php/IJEECS/article/view/3782/2115 |z Get fulltext |