Relative Biological Effectiveness Studies Using 3 MeV Proton Beam from Folded Tandem Ion Accelerator: An Experimental and Theoretical Approach

Proton being the easiest light ion to accelerate and achieve desired beam profile, has been pursued as a popular particulate radiation for therapy applications. In the present study, Saccharomyces cerevisiae D7 strain was used to estimate the RBE values of the 3 MeV proton beam, and an attempt was m...

Full description

Saved in:
Bibliographic Details
Main Authors: Nairy, Rajesha K. (Author), Bhat, Nagesh N. (Author), Anjaria, K.B (Author), Yadav, Usha (Author), Chaurasia, Rajesh (Author), Shirsath, Kapil (Author), Desai, Utkarsha (Author), Gupta, S.K (Author), Sapra, B.K (Author), Yerol, Narayana (Author)
Format: Ebooks
Published: IntechOpen, 2020-11-28.
Subjects:
Online Access:Get Online
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Proton being the easiest light ion to accelerate and achieve desired beam profile, has been pursued as a popular particulate radiation for therapy applications. In the present study, Saccharomyces cerevisiae D7 strain was used to estimate the RBE values of the 3 MeV proton beam, and an attempt was made to derive mathematical formula for calculating RBE value with respect to the dose. Dosimetry studies were carried out using Fricke dosimetry and Semiconductor Surface Barrier detector to calibrate the absorbed doses of Gamma chamber-1200 and Folded Tandem Ion Accelerator respectively. Gold standard cell survival assay and gene conversion assay were used to compare gamma and proton radiation induced cell death and genetic endpoint. Multi target single hit model was used to derive mathematical formula for RBE estimation. The results show a linear survival-dose response after proton radiation and sigmoid survival-dose response after gamma radiation treatment. The calculated RBE value from the survival and gene conversion studies was 1.60 and 3.93, respectively. The derived mathematical formula is very useful in calculating RBE value, which varies from 3.61 to 1.80 with increasing dose. The estimated RBE value from the mathematical formula is comparable with the experimental values. With the help of the present mathematical formulation, RBE value at any dose can be calculated in the exponential and sigmoidal regions of the survival curve without actually extending the experiment in that dose region, which is not possible using conventional methods.
Item Description:https://mts.intechopen.com/articles/show/title/relative-biological-effectiveness-studies-using-3-mev-proton-beam-from-folded-tandem-ion-accelerator