The present work deals with the experimental study on rehabilitation of damaged steel pipes. The process of rehabilitation was done by using adhesive bonded CFRP patch on damaged sites of the pipes with the help of vacuum bagging set-up. The reference optimal parameters to rehabilitate the damaged p...

Full description

Saved in:
Bibliographic Details
Main Authors: Chokka, Syam Kumar (Author), Satish Ben, Beera (Author), Sai Srinadh, Kowtha Venkata (Author)
Format: Ebooks
Published: IntechOpen, 2019-08-07.
Subjects:
Online Access:Get Online
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02283 am a22002173u 4500
001 intechopen_books_7679
042 |a dc 
100 1 0 |a Chokka, Syam Kumar  |e author 
700 1 0 |a Satish Ben, Beera  |e author 
700 1 0 |a Sai Srinadh, Kowtha Venkata  |e author 
245 0 0 |a Overhauling of Steel Pipes Using Vacuum Bagging Processed CFRP Patch 
260 |b IntechOpen,   |c 2019-08-07. 
500 |a https://mts.intechopen.com/articles/show/title/overhauling-of-steel-pipes-using-vacuum-bagging-processed-cfrp-patch 
520 |a The present work deals with the experimental study on rehabilitation of damaged steel pipes. The process of rehabilitation was done by using adhesive bonded CFRP patch on damaged sites of the pipes with the help of vacuum bagging set-up. The reference optimal parameters to rehabilitate the damaged pipes were considered from the tensile test (tensile shear load) conducted on plates. The rehabilitated pipes were tested under hydrostatic pressure. The two-component structural adhesive (Araldite AW105 and Hardener HV 953U) used in this study has high viscosity. It is not desirable for CFRP composite making and may lead to improper penetration of adhesive through open pores of the adherent surface. The viscosity of the adhesive was reduced in two ways: addition of a low viscous two-component nonstructural adhesive (Araldite LY-1564 and Aradur-22962) and heating the adhesive. Vacuum pressure, bond length and pre-bond surface preparation of the adherents were considered as parameters to evaluate the bond strength. The roughness of different samples was studied using a 3D microscope. The surface morphology of adherent was studied using scanning electron microscopy (SEM). Based on the experimental studies, it is observed that the optimal conditions of the tensile data of the plates hold good for the rehabilitated pipe under hydrostatic loading. 
540 |a https://creativecommons.org/licenses/by/3.0/ 
546 |a en 
690 |a Adhesives and Adhesive Joints in Industry Applications 
655 7 |a Chapter, Part Of Book  |2 local 
786 0 |n https://www.intechopen.com/books/7679 
787 0 |n ISBN:978-1-78984-898-4 
856 \ \ |u https://mts.intechopen.com/articles/show/title/overhauling-of-steel-pipes-using-vacuum-bagging-processed-cfrp-patch  |z Get Online