Analysis of Deoxygenation and Reoxygenation Rate in the Indonesia River (A Case Study: Bedadung River East Java)

Bedadung River is the main river in the Jember Regency - East Java. The organic and inorganic waste from human activity increases potential pollution loads in the river. The pollution load impacts on the water quality of the river. The oxygen existence as an indicator of river water quality that was...

Full description

Saved in:
Bibliographic Details
Main Authors: PRADANA, Hendra Andiananta (Author), NOVITA, Elida (Author), WAHYUNINGSIH, Sri (Author), PAMUNGKAS, Rifan (Author)
Format: Academic Paper
Published: IOP Conf. Series: Earth and Environmental Science 243 (2019) 012006, 2020-07-20T16:46:10Z.
Subjects:
Online Access:Get Fulltext
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02304 am a22002773u 4500
001 repository_unej_123456789_99833
042 |a dc 
100 1 0 |a PRADANA, Hendra Andiananta  |e author 
500 |a http://repository.unej.ac.id/handle/123456789/99833 
500 |a KODEPRODI1710201#Teknik Pertanian 
500 |a NIDN0030117302 
500 4 1 |u NIDN0030117204 
700 1 0 |a NOVITA, Elida  |e author 
700 1 0 |a WAHYUNINGSIH, Sri  |e author 
700 1 0 |a PAMUNGKAS, Rifan  |e author 
245 0 0 |a Analysis of Deoxygenation and Reoxygenation Rate in the Indonesia River (A Case Study: Bedadung River East Java) 
260 |b IOP Conf. Series: Earth and Environmental Science 243 (2019) 012006,   |c 2020-07-20T16:46:10Z. 
520 |a Bedadung River is the main river in the Jember Regency - East Java. The organic and inorganic waste from human activity increases potential pollution loads in the river. The pollution load impacts on the water quality of the river. The oxygen existence as an indicator of river water quality that was determined based on deoxygenation and reoxygenation rate. It was one of decision making for the government on water quality management in the watershed. This research aims analyzed pollution loads, deoxygenation and reoxygenation rate of Bedadung River in the Patrang - Sumbersari segment. Simple mathematical analysis model oxygen distribution used the Streeter-Phelps method. This method applied dissolved oxygen data (DO) and biological oxygen demand (BOD) as the input data. The results represented that the highest pollution loads at point 7 in value 1198.6 kg/day. Based on the calculation of oxygen distribution with Streeter-Phelps formula, the rate of deoxygenation (rD) < reoxygenation (r R ) a sequence were 0.028 mg/day.L and 0.053 mg/day.L. It indicated a good functioning for pollutant degradation. The government and stakeholder had been maintained through an integrated water quality management scheme and pollution control on the Bedadung River. 
546 |a en 
690 |a deoxygenation 
690 |a reoxygenation 
690 |a rate in the Indonesia River 
690 |a Bedadung River East Java 
655 7 |a Article  |2 local 
787 0 |n http://repository.unej.ac.id/handle/123456789/99833 
856 4 1 |u http://repository.unej.ac.id/handle/123456789/99833  |z Get Fulltext